Electric vehicles
Scope: deterministic fixed-assignment AC charging, smooth NLP or NLP with complementarity. Evidence: analytical cases and regression tests; no fleet-wide calibration or field-performance claim.
A charging schedule must meet the departure-energy requirement within the vehicle and charger ratings. PowerOptLab represents availability, equipment limits, stored energy and optional state-dependent charging acceptance. Pilot-response dynamics are not represented.
Charging studies
| Question | Model and additional evidence |
|---|---|
| Can a parked vehicle obtain its requested energy? | PE energy account, session, equipment ratings and AC network |
| Which phase or conductor is limiting? | Explicit connection, per-conductor ratings and phase policy |
| Does charging taper change deadline feasibility? | Calibrated acceptance envelope and time-grid refinement |
| Is V2G profitable over repeated operation? | Equal or economically valued terminal state, losses, tariffs; aging for lifetime claims |
| Does the proposed dispatch track real equipment? | Requires a response/replay model and measured pilot/charging data |
| Can a fleet promise a network service? | Requires disaggregation, uncertainty and delivery-duration validation |
The literature notes distinguish research findings from our implementation choices. More detailed battery physics is useful only when the data support it; see PE versus IVQ.
Choose a starting point
| Your task | Guide |
|---|---|
| Derive energy, port and operating-mode constraints | Scientific model and solvers |
| Model a vehicle, an AC outlet and a fixed visit | Equipment, energy and sessions |
| Use the compact compatibility constructor | EVDevice model |
| Run a complete feeder charging comparison | Workplace feeder study |
| Understand simultaneous charging, V2G and solver choices | Artificial cycling and arbitrage |
| Inspect a specific complementarity-backend result | CCOpt zero-dispatch investigation |
| Assess taper and smoothing assumptions | Taper, smoothing and flexibility |
| Look up constructors and fields | EV API |
| Assess scientific precedent and evidence limits | Literature evidence |
| Identify unsupported studies and missing model layers | Scope and limitations |
| Reproduce studies using earlier defaults | Compatibility and migration |
The session and workplace examples show charging at assigned outlets. The sections below describe the vehicle, outlet and visit data; the model guide gives the electrical and energy-balance equations.
Vehicle, outlet and visit data
| Model | Quantities and constraints | Additional assumptions needed |
|---|---|---|
EV | Capacity/bounds, AC-referred onboard limits, efficiency, phase capability, optional acceptance curve | Location or a reusable initial state for multiple visits |
EVSE | One fixed AC outlet, conductor mapping, equipment P/Q/S/I ratings, operational availability | An onboard converter, a DC cabinet, or independent Q support while empty |
ChargingSession | Fixed EV–EVSE association, occupancy, initial energy, departure target, V2G/Q permission | A driving model or an optimized assignment |
EVDevice | Compact legacy combination of energy and network-port parameters | Equipment identity, occupancy conflict detection, trip energy |
AC conversion occurs onboard the vehicle; DC charging requires offboard conversion and potentially shared power electronics. The present EVSE is explicitly an AC outlet envelope. It does not double-count an onboard converter by adding another inverter at the outlet. Background and source: NREL EVSE technical overview.
A complete fixed session
using PowerOptLab
car = EV(id="car", energy_max=40e3,
onboard_charge_max=7e3, eff_charge=0.9)
outlet = EVSE(id="outlet", bus="poc", s_max=22e3, i_max=32.0)
visit = ChargingSession(id="visit", ev=car, evse=outlet,
available=[false,true,true,false],
energy_init=10e3, departure_energy=16.3e3)
result = solve_multiperiod_opf(nets, [visit];
time_grid=TimeGrid([1.0,0.5,0.5,1.0]))
d = result.dispatch["visit"]
d.energy_wh, d.current_magnitude_a, d.diagnosticsHere nets contains four parsed AC networks with bus poc. A self-contained network and executable version are supplied in examples/ev_charging.jl and the session tutorial.
available in a session means occupied, including periods when its EVSE is out of service. The EVSE's separate mask controls electrical availability. Sessions must occupy one contiguous interval; their departure is the end of the last occupied interval. departure_period can be supplied explicitly but must agree with that boundary. energy_init is a horizon-start stored-energy value; energy is held before arrival. No driving energy is inferred.
Different vehicles can use the same outlet successively. Overlapping occupancy, conflicting specifications with the same EVSE id, and repeated sessions for one EV id are rejected. The last restriction prevents accidental state resets; it is not a general mobility model. Distinct outlet ids at the same bus are allowed.
Permissions and capability intersections
Charging cannot exceed either the onboard or outlet power rating. The AC current and apparent-power constraints apply in addition. V2G requires a positive vehicle discharge limit, positive EVSE discharge limit, and allow_v2g=true. Q is zero unless allow_reactive_power=true; then the vehicle and EVSE Q intervals are intersected. Measured charger reactive consumption is not the same as controllable reactive capability.
For multiple phases, the default is equal phase P and equal phase Q. This is equal power, not balanced current under unequal voltages. Independent phase redistribution requires phase_policy=:independent on both the EV and EVSE. Set phase_count on the EV to match the fixed outlet connection. There is no phase-switching decision.
Units, solver settings and compatibility
- Powers and ratings are W/var/VA; energy is Wh; current is A; duration is hours.
energy_whis the explicit PE state name.socretains the same Wh values for compatibility. Neither is IVQ's dimensionless charge-based SoC.StorageDeviceandEVDevicenow default tooperation=:relaxed, a finite normalized charge/discharge product bound. This changes the old feasible set.operation=:complementaritysupplies exact mathematical mode exclusion to an MPCC backend.:independentexplicitly restores the outer relaxation.- All multi-phase PE devices require
i_max. Legacy single-phase devices may omiti_maxands_max, retaining a declared power-only abstraction. - A disconnected port has every phase-current component fixed to zero.
solve_status(result).publishablechecks solver convergence. Check the electrical and energy-balance residuals separately. A converged local solution does not establish global optimality.
See equations and solver choices, mode misconceptions, approximation and flexibility, and scope and limitations. The workplace feeder tutorial demonstrates equipment-dependent cost and deadline feasibility. Existing studies should read the compatibility and migration review.