HELM power-flow API
The HELM guide describes the supported load models, power-series calculation and convergence diagnostics. The power-flow comparison examines agreement with an iterative solution and the interpretation of failed calculations.
PowerOptLab.solve_pf_helm — Function
solve_pf_helm(net; config=_DEFAULT_CONFIG, switches=:alias,
ideal_xfmrs=:constrain, max_order=40, tol=1e-8,
embedding=:load_scaling, source_reference=:earth)
-> Dict{String,Any}Solve the power flow with HELM (helm_series) and return the standard result dictionary (SI units, same "bus" shape as the OPF results, compatible with write_result/read_result).
Top-level keys:
"termination_status"—"HELM_CONVERGED"|"HELM_SERIES_DIVERGED"(the computed coefficient tail is growing) |"HELM_MAX_ORDER"(series order exhausted before the tolerance was met). Neither non-converged status is a proof of power-flow non-existence."feasible"—trueiff converged."solve_time"— wall-clock seconds."bus"—bus_id => terminal => {vr, vi, vm [V], va [rad]}. NaN-filled when HELM does not converge (the standard infeasible convention)."coupling"—id => conductor => {kind, ir, ii [A], im [A]}: the PHYSICAL current through each ideal coupling (closed-switch conductor withswitches = :constrain, ideal-transformer winding core)."source_injection"—bus_id => terminal => {ir, ii, im [A]}: current injected into the network by the voltage-source boundary."helm"— diagnostics:order,residual(A), rawpade_spread,coefficient_tail_norms,coefficient_tail_ratios, the heuristicsingularity_estimate, and theembedding/source_referenceused.load_marginis retained as a compatibility alias.
PowerOptLab.helm_series — Function
helm_series(net; config=_DEFAULT_CONFIG, switches=:alias,
ideal_xfmrs=:constrain, max_order=40, tol=1e-8,
embedding=:load_scaling, source_reference=:earth) -> HelmResultSolve the unbalanced multiconductor power flow of net with the Holomorphic Embedding Load-flow Method on the augmented nodal admittance matrix. Every explicit conductor (neutral, PE, …) keeps its own node.
Deterministic and non-iterative: no initial guess, one LU factorization for the germ and every series order. A converged result is the operational branch continuously connected to the germ. A non-converged result reports whether its finite coefficient tail grew (:series_diverged) or merely exhausted the requested order (:max_order_reached); neither is a proof that no power-flow solution exists.
Keywords:
switches,ideal_xfmrs— forwarded toybus_augmented;switches = :constrainadditionally yields every switch-conductor current.max_order— highest series order (default 40).tol— relative convergence tolerance on the s = 1 current mismatch, scaled by the largest load-current magnitude.embedding—:load_scaling(default; the germ is the energized no-load network and the embedding parameter is a load multiplier) or:impedance_germ(constant-impedance parts in the matrix, other load parts blended from an equivalent admittance at the germ — needed when a node is held only by loads, e.g. an unearthed star point).source_reference—:earth(default; source phase terminals fixed to their phasors and the source-bus neutral to 0 V, as in the OPF) or:neutral(phasors imposed phase-to-source-neutral; the source neutral floats with the network's earthing, so neutral-earthing impedances at the source are honoured).
Supported loads: constant power, constant current, constant impedance, ZIP and exponential models in WYE, DELTA and SINGLEPHASE connections. Networks with generators or IBRs raise an ArgumentError: they have no fixed power-flow law in the data model and are not silently dropped. Transformer support and validation follow `ybusaugmented: small or singular leakage is retained in bordered winding ports, finite shunts are included exactly once, andideal_xfmrs = :stamp` rejects units that require a border. Floating references and redundant ideal cycles may still make the germ singular.
PowerOptLab.HelmResult — Type
HelmResultResult of helm_series — the HELM power-flow solution and its diagnostics.
Fields:
V—Dict{(bus,terminal),ComplexF64}node-to-earth voltages ats = 1(every declared terminal, including source/fixed, aliased, and earth-referenced ones).w— unscaled bordered-row solution entries; the PHYSICAL current ofcouplings[j]iscouplings[j].scale * w[j].couplings— theIdealCouplings of the underlyingybus_augmentedmatrix, inworder.coeffs— series coefficients, one row per unknown (non-fixed nodes, then couplings, then source constraint rows) and one column per order (diagnostic).converged—trueiff the s = 1 nonlinear current mismatch is within tolerance.status—:converged|:series_diverged(the finite coefficient tail is growing) |:max_order_reached.residual— max |current mismatch| (A) over every non-Dirichlet node (source-bus terminals included when they are unknowns) and every constraint row, evaluated at the returned solution.n_order— highest series order computed.pade_spread— absolute difference between the last two Wynn-epsilon Padé estimates for each row ofcoeffs. Values have the units of their corresponding row.coefficient_tail_norms— max-norm of the final coefficient orders used by the status classifier.coefficient_tail_ratios— adjacent ratios of those tail norms. A tail with every ratio above one is classified as:series_diverged.singularity_estimate— heuristic Domb–Sykes estimate of the nearest coefficient-dominating singularity in the embedding parameter. Underembedding = :load_scalingthat parameter is a load multiplier; it is never a certified loading margin.NaNmeans the series is too short or featureless.source_injection—Dict{(bus,terminal),ComplexF64}current (A) injected INTO the network by the voltage-source boundary at each node it acts on: the slack phase currents, and, withsource_reference = :earth, the earthing current of the fixed source neutral.embedding,source_reference— the embedding options used.
result.load_margin remains a compatibility alias for result.singularity_estimate; new code should use the latter name.